Stability of Implants Placed in Patients With Vitamin D Deficiency Using Sequential Drilling vs a Single Drilling Design
追踪信息 | |||
---|---|---|---|
首次提交日期 ICMJE | September 30, 2018 | ||
首次发布日期e ICMJE | October 4, 2018 | ||
最后更新发布日期 | October 5, 2018 | ||
预计研究开始日期 ICMJE | November 27, 2018 | ||
预计主要完成日期 | November 27, 2020 (主要结果测量的最终数据收集日期) | ||
目前主要观察指标 ICMJE |
primary/secondary implant stability[ Time Frame: 6 months ] primary & secondary implant stability using ostell/periotest |
||
原始主要观察测量 ICMJE | 与当前相同 | ||
目前的二级观察 ICMJE |
|
||
描述性信息 | |||
简略标题 ICMJE | Stability of Implants Placed in Patients With Vitamin D Deficiency Using Sequential Drilling vs a Single Drilling Design | ||
正式标题 ICMJE | Stability of Dental Implants Placed in Patients With Vitamin D Deficiency Using Sequential Drilling Versus a New One Single Drilling Design: A Randomized Clinical Trial | ||
简要概况 | - Vitamin D considers as the most potent effect on calcium level in blood it was found that vitamin D target mainly bone tissue intestine and kidney for calcium absorption In bone, vitamin D stimulates mainly the activity of osteoclasts osteoblast activity on the other hand it increases the production of extracellular matrix proteins by different osteoblastic activity. Vitamin D also increase intestinal calcium absorption and regulate synthesis and secretion of parathyroid hormone (PTH) Implant consider as one of the most successful treatment modalities that usually used in dental clinics for restoring single or multiple missed teeth knowing that successful rate of dental implant may reach up to 99% however there are many different techniques for implant placement they mainly depend on the same procedure for implant placement even sequential drilling technique or single drilling technique some paper supported that sequential drilling is much better than single drilling technique on other hand some assume that single drilling is much better as it save time effort material less bone trauma & less heat generation although there are many studies performed on sequential drilling & single drilling techniques we still have a gap for understanding the ideal technique for implant placement in patients with vitamin D deficiency |
||
详细说明 | The high predictability of dental implants has led to routine use with a great expectation for success There are many researches focused on the outcome of delayed dental implant Since the first report of highly success rate after placement of a dental implant there has been increasing interest in this technique for implant treatment The goal of modern dentistry is to restore the patient's dentition to normal contour function comfort esthetics speech and health regardless of the atrophy disease or injury of the stomatognathic system As a result of disease related tooth loss and the value placed upon teeth there has been a continual search for methods by which missing teeth could be replaced Early artificial replacements were made from natural teeth and a variety of substitute materials All transplantation of a tooth from one person to another was an early method by which lost teeth were replaced Archeological discoveries indicate that many ancient civilizations practiced allogenic tooth transplantation. In 1561 Ambrose Pare reported that decayed teeth could be replaced by using extracted teeth from another individual and is credited with being the first to mention transplantation The core objective of dental implant therapy is to improve functional dentition throughout life Nevertheless there are many factors that may effect on implant stability A significant part of implant failure may be related to systemic condition that my retard dental implants osteointegration one of this factors is vitamin D deficiency recently many paper focused on vitamin D deficiency and its impact effect on bone turn over around dental implant There are many different techniques for implant placement even sequential drilling or single drilling technique knowing that single drilling technique has a compression effect which may enhance implant stability however sequential drilling don't have compression effect on bone some paper supported that sequential is much better than single drilling technique however some paper showed there is no clinical significance between two techniques the main idea here that we need to find an ideal technique for implant placement in patients with vitamin D deficiency knowing that vitamin D play an important role for bone turnover around dental implant to attain the required dental implant stability also play a role for osteoblast osteoclast activity Also vitamin D play a role for regulation of parathyroid hormone which play a role for homeostasis of calcium level from bone in blood . | ||
研究类型 ICMJE | Interventional | ||
研究阶段 | Phase 4 | ||
研究设计 ICMJE | 分配: Randomized 干预模型: Parallel Assignment 干预模型描述: 盲法: Interventional 盲法描述:double blinded 主要目的: Treatment |
||
适用条件 ICMJE | |||
干预项目 ICMJE |
|
||
研究工具 |
|
||
招募信息 | |||
招募状态 ICMJE | Not yet recruiting | ||
预计入组 ICMJE |
20 | ||
原始预计入组 ICMJE | 与当前相同 | ||
预计研究完成日期 | March 27, 2021 | ||
预计主要完成日期 | November 27, 2020 (主要结果测量的最终数据收集日期) | ||
合格标准 ICMJE | Inclusion criteria: 1. Age: 18-70. 2. Patient with vitamin D deficiency ( >30 ng/ml ) 3. Patients with single or multiple missed teeth in upper & lower molar premolar area. 4. Patients with adequate bone volume for the dental implant procedure. 5. Patient with sufficient interarch space. 6. Patients who are compliant to oral hygiene measures. 7. Patient consent approval and signing. Exclusion criteria: 1. Systemic disease that contraindicates implant placement or surgical procedures. 2. Poor patient's compliance. 3. Psychological problems. 4. Pathology at the site of intervention. | ||
性别 |
|
||
年龄 | 最小年龄:18 Years ,最大年龄:N/A | ||
接受健康的志愿者 | 没有 | ||
可入组国家 ICMJE | |||
管理信息 | 数据检测委员会 | No | |
研究涉及美国FDA监管的产品 |
研究美国FDA监管的药品: No 研究涉及美国FDA监管的设备产品: No |
||
IPD 共享声明 |
|
||
责任方 | Ahmed Nabil Ahmed Younis,Cairo University | ||
研究赞助商 ICMJE | Cairo University | ||
合作者 ICMJE | |||
研究员 ICMJE |
|
||
PRS 账户 | Cairo University | ||
验证日期 | October 2018 | ||
ICMJE 国际医学期刊编辑委员会和 世界卫生组织 ICTRP 要求的元素 |